Dimensions
|
|
Nominal Size
|
1-5/8 in
|
|
Bonding Conductor Length
|
1524.0 mm | 60 in
|
|
Cable Jacketing Removal Length, maximum
|
59.1 mm | 2.3 in
|
|
Cable Jacketing Removal Length, minimum
|
55.9 mm | 2.2 in
|
|
Compatible Diameter, maximum
|
50.800 mm | 2.000 in
|
|
Compatible Diameter, minimum
|
49.022 mm | 1.930 in
|
|
Enclosure Length
|
80.0 mm | 3.2 in
|
|
Enclosure Width
|
69.9 mm | 2 3/4 in
|
|
|
|
Electrical Specifications
|
|
Current Handling
|
Tested to withstand 100,000 amps peak current surge
|
|
Current Handling Test Method
|
MIL-STD-1757
|
Grounding, Bonding and Shielding Test Method
|
MIL-STD-188-124A
|
Lightning Protection Test Method
|
IEC 1024-1
|
|
|
|
General Specifications
|
|
Cable Type
|
Corrugated
|
|
Grounding Kit Type
|
Compact SureGround™ Grounding Kits
|
|
Color
|
Black
|
|
Bonding Conductor Material
|
Copper
|
|
Bonding Conductor Wire Size
|
16 mm²
|
|
Bonding Conductor Jacketing Material
|
PE
|
|
Grounding Strap Material
|
Copper
|
|
Includes
|
Grounding kit | Hardware | Lug
|
|
Locking Bail Material
|
Stainless steel
|
|
Lug Attachment
|
Field attached
|
|
Lug Type
|
Two-hole lug
|
|
Package Quantity
|
1
|
|
Rivet Material
|
Copper
|
|
Weatherproofing Method
|
Copper strap contact overmolded with EPDM rubber
|
|
|
|
Mechanical Specifications
|
|
Blowing Rain Test Method
|
MIL-STD-810, Method 506
|
|
Corrosion Test Method
|
MIL-STD-1344, Method 1001
|
|
Freezing Rain/Icing Test Method
|
MIL-STD-810, Method 521
|
|
Humidity Test Method
|
MIL-STD-1344, Method 1002
|
|
Immersion Test Method
|
IEC 60529:2001, IP68
|
|
Operating Temperature
|
-40 °C to +85 °C (-40 °F to +185 °F)
|
|
Storage Temperature
|
-40 °C to +80 °C (-40 °F to +176 °F)
|
|
Thread Size
|
3/8 in
|
|
UV Resistance Test Method
|
MIL-STD-810, Method 505
|
|
Vibration Test Method
|
MIL-STD-202, Method 214
|
|
|
|
Packed Dimensions
|
|
Height
|
260.4 mm | 10.3 in
|
|
Length
|
82.6 mm | 3.3 in
|
|
Shipping Weight
|
0.46 kg | 1.02 lb
|
|
Width
|
203.2 mm | 8.0 in
|